The D-2+ series instruments are fully functional and highly adaptable, and are widely used in static weighing systems using 1 to 8 sensors, such as electronic floor scales, electronic truck scales, and static track scales.

  • A/D conversion method: double integral
  • A/D conversion rate: 50 times/second
  • Maximum A/D conversion number: ≈700,000
  • Input signal range: 0mV~30mV
  • Input sensitivity: ≥1μV/e
  • Sensor bridge power supply: DC15V; I≤350mA
  • Number of connected sensors: 8 350Ω sensors can be connected
  • Sensor connection mode: 6-wire system, automatic compensation for long lines, compensation distance ≤ 50 meters
  • Verification division number: 3000
  • Maximum external division number: 30000
  • Graduation value: 1/2/5/10/20/50/100 optional
  • Display mode: 6-digit VFD digital tube, 6 status indicators
  • Display range: -99990 to 320000 (e=10)

 

  • High-precision A/D conversion, readability up to 1/30000;
  • Zero tracking range and zero setting (power on/manual) range can be set separately;
  • Automatic/manual, daily report/classification statistical report printing settings;
  • Quick-fill weighing slip printing function setting;
  • Store 255 vehicle numbers and corresponding tare weights, 100 cargo numbers, and 512 sets of weighing records;
  • Weighing record storage/check/deletion/power-off protection;
  • Manual linear correction calibration;
  • Up to 5-point nonlinear correction reduces the restrictions on system accessories;
  • Equipped with RS-232 communication port, optional baud rate and communication mode;
  • Equipped with a large screen communication port, with two connection modes: 20mA current loop (constant current source) and RS-232;
  • Equipped with a standard parallel printing interface, which can be connected to a 9-pin or 24-pin wide line printer;
  • D2+ has a built-in 16-column panel-type micro printer;
  • Recommended non-standard modified varieties:
  • Improved model with fast horizontal triple-fill printing function;
  • Modified model with automatic record storage over limit and password deletion function;